Latest Cisco CCNP Data Center 300-180 dumps, 300-180 exam practice test questions and answers

Real and effective Cisco CCNP Data Center 300-180 dumps, online Cisco 300-180 exam practice test, free online download 300-180 pdf! Pass the 300-180 exam “Troubleshooting Cisco Data Center Infrastructure (DCIT)”: https://www.leads4pass.com/300-180.html (434 Q&As) Follow me! Get more latest effective exam dumps!

[PDF] Free Cisco CCNP Data Center 300-180 pdf dumps download from Google Drive: https://drive.google.com/open?id=10dof3jhMFuQ5wy-kXBADQrDDPAt_Mc8r

[PDF] Free Full Cisco pdf dumps download from Google Drive: https://drive.google.com/open?id=1CMo2G21nPLf7ZmI-3_hBpr4GDKRQWrGx

300-180 DCIT – Cisco: https://www.cisco.com/c/en/us/training-events/training-certifications/exams/current-list/dcit.html

Free test Cisco CCNP Data Center 300-180 Exam questions and Answers

QUESTION 1
Which statement about the Nexus atomic rollback feature is true?
A. It restores the default manufacturing configuration.
B. Each error must be acknowledged prior to implementation.
C. It is implemented only if no errors occur.
D. It is implemented and any errors are skipped.
Correct Answer: C
Reference: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/5_x/nx-os/system_management/configuration/guide/sm_nx_os_cg/sm_7rollback.htm

QUESTION 2
Which statement is true about the show cfs merge status name command?
A. In a successful merge, all switches in the fabric are shown separately.
B. The command shows the complete Cisco Fabric Services region database.
C. The merge master is selected based on the highest sWWN in the fabric.
D. In a successful merge, all switches are shown in a local fabric.
Correct Answer: D

QUESTION 3
Refer to the exhibit.lead4pass 300-180 exam question q3

The customer informs you of a problem they are encountering. What is the cause of the problem?
A. The core upstream switch does not have NPIV enabled.
B. The downstream switch does not have NPIV enabled.
C. NPIV has been disabled on all switches.
D. NPIV has been configured but not enabled on the uplink port.
Correct Answer: A

QUESTION 4
An administrator wants to combine the advantages of a trunking F port and an F port channel.
Which command on a Cisco MDS switch should be used to enable this?
A. enable port-channel
B. feature trunking-fport
C. feature fport-channel-trunk
D. port-channel trunk
E. feature fport-trunk
Correct Answer: C

QUESTION 5
You successfully install VMware ESXi 5.0 U1 on a Cisco UCS B200 M3 server to a Fibre Channel LUN. When you
reboot the server, you see the message “Reboot and Select Proper Boot device or insert Boot Media in selected Boot
device and press a key.” What are the first two pieces of information you should gather to troubleshoot the boot failure?
(Choose two.)
A. Connect to the NX-OS shell via the CLI and run the show npv flogi-table command.
B. SSH to the MDS 9124 and run the show flogi database command.
C. Validate the boot target WWPN and LUN ID in the service profile.
D. Validate the correct source WWPN in the service profile vHBA definition.
E. Validate zoning for your WWPN on the Cisco MDS 9124.
F. Validate that the boot order indicates the vHBA as the first device.
G. Ensure LUN masking is correctly configured on the storage controller.
Correct Answer: CF

QUESTION 6
What are the minimum number and maximum number of members that a SAN PortChannel can have?
A. 1, 16
B. 2, 16
C. 1, 32
D. 2, 32
E. 1 minimum with no maximum
F. 2 minimum with no maximum
Correct Answer: A

QUESTION 7
You have a Cisco UCS Central cluster. An I/O error is detected in the shared storage. What is a possible cause of the
issue?
A. One of the Cisco UCS Central nodes is powered off.
B. The wrong path selection policy is configured in VMware.
C. The shared storage LUN was shared by a virtual machine other than the Cisco UCS Central cluster nodes.
D. The Cisco UCS domain is not registered in Cisco UCS Central.
Correct Answer: C

QUESTION 8
Which three of these would cause two switch fabrics not to merge? (Choose three.)
A. Two or more switches do not have at least one assigned domain ID in common.
B. Two switches have different assigned VSANs on the connecting ports.
C. Two switches have different assigned VLANs on the connecting ports.
D. The static domain ID does not override the dynamic ID.
E. The election of the static domain is only determined by the WWNs of the two switches.
F. The physical connectivity between the two switches is not active.
Correct Answer: ABF

QUESTION 9
You install a new DIMM in a Cisco UCS C-Series standalone rack server and that DIMM is not recognized by the server.
What actions do you take to troubleshoot the problem? (Choose two)
A. Remove an old DIMM from the blue memory slot and install the new DIMM there.
B. Verify that the DIMM has been qualified to work on Cisco UCS servers.
C. Return the DIMM for a new replacement.
D. Remove and dispose of the bad DIMM.
E. Verify that the DIMM is in a slot that supports an active CPU.
Correct Answer: BD

QUESTION 10
A customer is configuring an upstream disjoint Layer 2 network in a Cisco UCS domain. So far they have configured the
following:
Fabric Interconnects are in switching mode.
There is a symmetrical configuration for high availability.
There are no overlapping VLANs.
Each vNIC is communicating with one disjoint Layer 2 network.
After validating the above, the customer is still having issues with network connectivity. What is the issue?
A. Overlapping VLANs are allowed in a disjoint Layer 2 network.
B. The vNIC configuration is incorrect and must communicate with two or more disjoint layer 2 networks.
C. The fabric interconnects must be in end-host mode for a disjoint Layer 2 network.
D. Asymmetrical configuration for high availability needs to be configured.
Correct Answer: C

QUESTION 11
Refer to the exhibit.lead4pass 300-180 exam question q11

Which conditions can trigger on a Cisco Nexus device running FabricPath?
A. A switch connected to the Cisco Nexus device is running RSTP instead of STP.
B. A BPDU with bridge priority set to 61140 is received by the switch edge port.
C. The switch edge port in the STP domain is not configured as root.
D. VLAN is configured incorrectly on port-channel 100.
Correct Answer: C

QUESTION 12
Your customer has a dual Cisco Nexus 7010 Switches in its data center. Customer\\’s representatives want to know
how to determine if Cisco IOS ISSU is possible on the switches as they are upgrading to version 6.0.4. Which command
is useful to determine if the upgrade will be non-disruptive?
A. N7010-C1# show system redundancy ha status
B. N7010-C1# show incompatibility system
C. N7010-C1# install all
D. N7010-C1# show issue test bootflash:n7000-s1-system.6.0.4.bin
Correct Answer: C

QUESTION 13
Refer to the exhibit. When this configuration is entered on a fabric interconnect, which traffic is added as a source for a
monitoring session?lead4pass 300-180 exam question q13

A. the ingress traffic on uplink port 1 on slot 3
B. the ingress traffic on uplink port 3 on slot 1
C. the egress traffic on uplink port 1 on slot 3
D. the egress traffic on uplink port 3 on slot 1
Correct Answer: D

Share the latest Cisco CCNP Data Center 300-180 dumps and online exam exercises for free! 300-180 exam questions and answers! Improve your skills and exam experience! Pass the 300-180 exam: https://www.leads4pass.com/300-180.html (434 Q&As). Follow me! Get more up-to-date and valid exam dumps.

Related 300-180 Popular Exam resources

title pdf youtube 300-180 DCIT – Cisco lead4pass
Cisco 300-180 lead4pass 300-180 dumps pdf lead4pass 300-180 youtube 300-180 DCIT – Cisco https://www.leads4pass.com/300-180.html
Cisco CCNP Data Center       https://www.leads4pass.com/300-180.html
      https://www.leads4pass.com/300-160.html
      https://www.leads4pass.com/300-165.html
      https://www.leads4pass.com/300-170.html
      https://www.leads4pass.com/300-175.html
      https://www.leads4pass.com/642-035.html
      https://www.leads4pass.com/642-980.html
      https://www.leads4pass.com/642-996.html
      https://www.leads4pass.com/642-997.html
      https://www.leads4pass.com/642-998.html
      https://www.leads4pass.com/642-999.html

Lead4pass Promo Code 12% Off

lead4pass 300-180 coupon

Why Choose Lead4pass?

Lead4Pass helps you pass the exam easily! We compare data from all websites in the network, other sites are expensive, and the data is not up to date, Lead4pass updates data throughout the year. The pass rate of the exam is above 98.9%.

why lead4pass 300-180 exam dumps